Recommended initial oxygen settings to achieve ambient air PaO2 >60 mmHg

Recommended initial oxygen settings to achieve ambient air PaO2 >60 mmHg
PaO2 breathing room air (mmHg) FIO2 (percent) Nasal cannula setting to achieve approximate FIO2 (L/min)
50 24 1
45 28 2
40 32 3
35 35 4